GeneSys Mid-Size: Scrub head circuit breaker tripped

Operational items to review that can cause circuit breaker to trip

Inadequate solution for application

  • Lack of sufficient cleaning solution can lead to excessive brush motor resistance

    • Increase solution flow to reduce excessive friction causing circuit breaker to trip

GeneSys - solution control


Scrub head set on heavy down pressure

  • Reduce down pressure to match required cleaning need

GeneSys - pressure selector

    • Daily cleaning

      • Select low solution flow
      • Select low down pressure (setting #1)
      • Select moderate to high speed
    • Project work / heavily soiled floor

      • Select medium solution flow
      • Select medium down pressure (setting #2)
      • Select low to moderate speed
    • Floor finish removal (Orbital version only with maroon scrub pad)

      • Select low solution flow
      • Select medium or high down pressure (setting #2 or #3)
      • Select very low speed

Note: Circuit breakers weaken when tripped frequently, causing breaker to trip under lower electrical load