GeneSys Mid-Size: Scrub head circuit breaker tripped
Operational items to review that can cause circuit breaker to trip
Inadequate solution for application
-
Lack of sufficient cleaning solution can lead to excessive brush motor resistance
- Increase solution flow to reduce excessive friction causing circuit breaker to trip

Scrub head set on heavy down pressure
-
Reduce down pressure to match required cleaning need

-
-
Daily cleaning
- Select low solution flow
- Select low down pressure (setting #1)
- Select moderate to high speed
-
-
-
Project work / heavily soiled floor
- Select medium solution flow
- Select medium down pressure (setting #2)
- Select low to moderate speed
-
Floor finish removal (Orbital version only with maroon scrub pad)
- Select low solution flow
- Select medium or high down pressure (setting #2 or #3)
- Select very low speed
-
Note: Circuit breakers weaken when tripped frequently, causing breaker to trip under lower electrical load