GeneSys Mid-Size: Short run time
Review settings that cause lower run time
Scrub deck set at high down pressure
-
High down pressure requires more energy to run, leading to reduced downtime
- Set down pressure to appropriate level for cleaning need
- Daily Cleaning
- Select low down pressure (setting #1)
- Daily Cleaning
- Set down pressure to appropriate level for cleaning need

Battery charging interrupted before cycle is fully completed
-
Review charger LED indicator to verify full charge cycle has been completed
- Locate charger beneath operator console of machine

- Review LED display on charger
Signal (LED)
Meaning
Red LED is on First phase of charging is in progress Yellow LED is on Second phase of charging is in progress Green LED is on End of charge or maintenance phase Yellow LED flashing Battery issue, battery not connected, or output short circuit Red LED flashing Safety time exceeded internal short circuit - Ensure green LED indicating charging has been completed is illuminated
- Locate charger beneath operator console of machine

Caution: Routinely interrupting charge cycle negatively impacts battery quality